Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12689217

- Product Categories
- Friendly Links
- home > Supply > Remote jet air conditioning unit | air conditioning units remotely jet production | Henderson Air Conditioning Equipment
Remote jet air conditioning unit | air conditioning units remotely jet production | Henderson Air Conditioning Equipment
Information Name: | Remote jet air conditioning unit | air conditioning units remotely jet production | Henderson Air Conditioning Equipment |
Published: | 2014-02-13 |
Validity: | 0 |
Specifications: | Limitation |
Quantity: | |
Price Description: | |
Detailed Product Description: | Remote jet air conditioning unit | air conditioning units remotely jet production | Horizon Air conditioning is provided by Horizon Air conditioning equipment. Texas Horizon Air Conditioning Equipment Co. (www.hxktsb.com) Business League Shandong Dezhou quality certified company, with Henderson air conditioning equipment and other brands, has a good reputation, honesty, service-oriented "business alliance Service" icon on the page We will be happy to serve you! Using ball-type nozzle outlet remote jet as air conditioning units and common ceiling air conditioning units in different remote jet air conditioning units, air conditioning units which are not anemometer pipe, mainly used for long-distance direct blast. Thermal performance parameters to calculate the air conditioning unit air conditioning units with the same general design selection mainly airflow calculations. For a building, when the blast from the air conditioning unit installation height, air temperature, indoor temperature, the air volume is virtually certain, you need to select the appropriate range jet air conditioning units, so that the jet of hot and cold air outlet of the unit sent to meet the following Requirements: ◆ cold wind to a designated location; ◆ Cold Jet is not halfway whereabouts, leading to human discomfort; ◆ blowing hot air can reach the distance and location requirements; ◆ end of the temperature difference between the design requirements; design selection should consider multiple units interaction between the outlet and the joint action. Diffusion width of the jet is about 0.4 times the distance range jet air conditioning unit sales, unit layout density slightly less than the diffusion width is appropriate. If the unit close to the ceiling, you should consider the impact of the attached. Attached flow range is about 1.4 times the normal flow. Dezhou, Shandong Hongxin air-conditioning plant air conditioning unit uses remote remote jet jet air conditioning unit applies to the following situations: a large space, want to reduce the time investment, saving air-conditioning running costs of the occasion; 2, the interior space does not allow installation of the upper duct or difficult installation of air duct occasions; 3, large space under the hot air is difficult to send occasions. For example: a large supermarket, factory workshop, stadiums, swimming pool, waiting hall, exhibition hall, foyer, lobby, etc.. Description: Remote jet air conditioning units and ceiling air conditioning units ordinary jet of air conditioning units in different remote processing, the air conditioning unit is not anemometer pipe, mainly used for long-distance direct blast. Thermal calculation and ordinary air conditioning units in the same unit, the design selection is mainly based on airflow calculations. For a building, when the blast from the air conditioning unit installation height, air temperature, indoor temperature, the air volume is virtually certain, you need to select the appropriate range jet air conditioning units, so that the jet of hot and cold air outlet of the unit sent to meet the following requirements: 1, hot and cold air to a designated location; 2, not the middle of a cold jet of air conditioning units whereabouts remote jet production, resulting in human discomfort; 3, the hot air can reach the distance and location requirements; 4, to meet the ends of the temperature difference design requirements of the unit consists of: box, fans, coolers, condensate tray, air, control, air filters and other components. Air conditioning unit is divided into horizontal and vertical; This unit works in a cooling, heating, drying, humidification function, while long-distance can be achieved without direct air duct, with a space-saving, lower storey, substantial time investment reduced, and low operating costs, while unit air angle of 60? within the scope of freedom of adjustment, to ensure cold wind to the designated location, creating a comfortable air-conditioned environment. Henderson, Texas conditioning plant |
Admin>>>
You are the 40216 visitor
Copyright © GuangDong ICP No. 10089450, Texas Air Conditioning Equipment Co., Ltd. Hongxin All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 40216 visitor
Copyright © GuangDong ICP No. 10089450, Texas Air Conditioning Equipment Co., Ltd. Hongxin All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility